7.1 Notes for operation

Various parameters can be set in the Casambi app and the status of the dimmer can be queried.

Before operation, please ensure that the dimmer is correctly calibrated and that the parameters match the connected load.

The functionality of the button inputs is defined via a parameter. Before the button inputs are configured via Casambi, a push-button style must be selected.



7.2 Operation with App

The device can be controlled via the Casambi App, available for iOS and Android. Another optional control is given by the push-button input.


With a slider you can adjust the brightness of a dimmer (from 0 ... 100%)

The brightness can be reduced  or increased  using the control elements.
and continuously adjusted  using the handle.


Another option is to swipe your finger horizontally over the device icon.




7.3 Sensors and parameter

Settings and parameters in the app


NOTE

In the Casambi world they are the terms sensors, parameters and information. Each of the terms stands for a specific type of value.
Here is the explanation:

Name

Meaning

Examples

Type

Sensors

display static values or technical-physical values of the environment

Consumption / Number of switching cycles

read only

Parameters

settings to achieve the desired functions or behavior

State after switching on: last value

writeable

Information

show values like manufacturer, model, or even detailed operating states of the device

RSSI: 78 dBm (radio reception quality)

read only

 

Sensors

Sensor nameDescriptionDefaultValue rangeEntity

Total consumed

Total consumed energy in Wh

0

0 ... 1.000.000

Wh
Current PowerPower currently consumed by the loadn.a.0 ... 1.000.000Wh
Load Current

Actual load current in mA

n.a.0 ... 1.000.000mA
TemperatureMomentary temperature at the measuring point (inside)n.a.
°C
On-Time DimmerNumber of operating hours devicepermanant0 ... 1.000.000h
On-Time LoadNumber of operating hours lamp/load00 ... 1.000.000h
On-Cycles DeviceNumber of power-ups devicepermanant0 ... 1.000.000cycles
On-Cycles LoadNumber of power-ups lamp/load > Brightness 000 ... 1.000.000cycles
Phase Angle

Phase Angle = Current phase angle of the dimmed output

  • 0 ° > Load is switched off
  • 1-179 ° > Phase cut is applied
  • 180 ° > Load is switched permanently on

n.a.

0 … 180°degree
System StatusSystem Status - Error Code
The parameter "System info" is derived from this error code.
-0, 1, 2, 4, 8, 16, 32number
Leading Edge
  • 0 > Trailing edge phase cut is used
  • 1 > Leading edge phase cut is used
n.a.0, 1digit

n.a. = not applicable


Parameter

Parameter nameDescriptionValue rangeEntityDefault
Unlock/ Lock SettingsTo unlock the following parameters, this value must be set to unlocked

locked

unlocked


locked
Measure ModeHere a measure mode can be preset with which a new calibration starts.

Automatic
Trailing Edge
Leading Edge
Zero Cross Switch


Automatic
Start MeasurementStart new calibration


Reset statisticsdelete statistics


Push-Button-Style

Behavior of the device button

  • Comfort - Casambi functions plus Comfort functions like e.g.
    double click = 100%; dimming; long key; load memory level function
  • Standard - Standard Casambi Push button input
    Behavior like a standard Casambi input

Comfort

Standard


Comfort

Load NumberDisplay load number - max. illuminants of the same type are displayed0...digits
System info

System status is displayed through a text. If there is no error, the text is "O.K.". If an error is present, the corresponding text is displayed. If several errors are present, the text of the error with the highest priority is displayed.

ErrorTextValuePriority
No errorO.K.0
Load output is openOpen11
Over temperature is activeOvertemp22
Load output has overvoltageOvervolt43
Load output has a short-circuitShort84
Shutdown by over temperatureSD temp165
Shutdown by short-circuitSD short326

digits
Dimming Curve

The dimming curve used can be selected, by default the linear curve is used. To get a different dimming behavior, the dimming curve can be selected. The Casambi curves 3 and 4 are intended when several dimmers from different manufacturers are operated together. 






Dimming Curve 

ModeDimming CurveValueType
linear

0linear curve - default
LEDPicture added soon1maintronic custom curve
incandescentPicture added soon2maintronic custom curve
Casmbi Standard

3Casambi Compatibility mode
Casambi Log

4Casambi Compatibility mode


7.4 Push-button mode

Through the parameter Push-button style the functionality of the button inputs are defined.

To change the push button style, proceed as shown below

  1. Open Casambi App
  2. Double tap on the device icon
  3. Scroll down to parameter
  4. Tap on Push-button style 
  5. Choose parameter
    (See the list below)


Push-button modeWertEnglish

Comfort

0

Casambi standard operations plus additional functions:

Casambi Funktionen plus Comfort Funktionen wie z.B.

Double-click = 100%; dimming; long key stroke; last memory level function

Standard

1 *

Standard Casambi Push button input

Behavior like a standard Casambi input with Casambi standard operations

* = Default

Casambi push-button-input = Behavior like standard Casambi push-button:

Remote control: "controls a luminaire, element, scene ..."




7.5 Operation with Push-button input

The device is equipped with a push-button input (Pin 5 u. 6), push-buttons with mains potential can be connected to this input. A push-button has the same priority as the Casambi App, the last one wins.


NOTE
The N must be connected to pin 5.

All wiring and the push-buttons must be insulated for the maximum supply voltage. Ensure the appropriate contact protection after installation. All push-buttons of the well-known switch manufacturers are suitable.

Please see the notes to the push-button styles.


Assign functions to a button

Function switch

Push-button inputs can be individually assigned with desired functions. 
In order to do this, the following steps are necessary:

  1. Open Casambi app and tap on „... More“
  2. Open item „Switch“
  3. Select device
  4. Scroll down do push-buttons
  5. Choose your maintronic module with push-button inputs
  6. For example program switch with single function 
    1. Select the item "Controls a luminaire"
    2. Tap on "Luminaire"
    3. Choose a device

Configure a button for a device

By default, the push-button is configured to itself.
If another device or scene should be controlled, proceed as follows:

  1. Proceed step 1-5 above
  2. Select the item
    1. controls an element for an element of any device
    2. or controls a luminaire for direct control of a luminair
    3. or controls a scene
  3. Open an element
  4. Open the "Element" item
  5. Select the desired element


NOTE
The function of the push-button input is defined with the parameter "Push Button mode" as follows in the app.


7.6 Operation with device button

The device button (1)  has the same priority as the Casambi App, the last command (action) wins.
Function device-buttonKeystroke

Switch On- / Off

Dim the last stored brightness

short press
Dimming Up and Down (Start at Min Level)long press
Switching to Max Level2x short press